F127 E-Stop, Light Curtain and Safety Gate Monitor3 Safety contacts N/O 1 Auxiliary contact N/C Single- / dual - channel operation Crossfault monitoring Monitored - / automatic reset Safety gate application Light curtain application Rated voltage: 230/115 VAC; 24 VAC/DC |
F20 E-Stop and Safety Gate Monitor with Solid State OutputsStop Category 0 Safety Category 4 (2) Solid State Safety Outputs (1) Solid State Aux Output Cross Fault and Ground Fault Monitoring Monitored or Automatic Start Compact 22.5mm Housing |
Tesch F23 Safety Gate Monitor with Solid State OutputsStop Category 0 Safety Category 4 (2) Solid State Safety Outputs (1) Solid State Aux Output, Monitors N/O or N/C contacts Cross Fault and Ground Fault Monitoring Monitored or Automatic Start Compact 22.5mm Housing |
F25 Two Hand Control Module with Solid State OutputsTwo Hand Control relay acc. to EN574 Type IIIC or IIIA, up to Cat 4 per EN954-1, (2) Solid State Safety Outputs (1) Solid State Aux Output Cross Fault and Ground Fault Monitoring 2 Channel Control Compact 22.5mm Housing |
F28 Safety Monitor with Delayed Solid State OutputsStop Cat 0/1 Safety Category 4 (2) Solid State Safety Outputs with Adjustable Off Time Delay (1) Solid State Aux Contact Monitored or Automatic Start 27 Time Ranges up to 300 Seconds Compact 22.5mm Housing |
F125 Two Hand Control RelayRelay conforms to standards EN 574section III C and EN 60204-1 (1998) 2 positively-driven NO contacts Up to 230V supply voltage Dual channel activation Crossfault monitoring Optional with removable terminals |
F131 E-Stop, Light Curtain, Safety Mat and Safety Gate Monitor3 Safety contacts N/O 2 Auxiliary contacts N/C 2 Semiconductor outputs Single- / dual - channel operation Crossfault monitoring Monitored - / automatic reset Safety gate application Light curtain application Safety mat application Rated voltage: 230 / 115 / 42 VAC; 24 VAC/DC |
F138 Safety Monitor with Timer2 instantaneous contacts: Stop Category 0 Safety Category 4 3 off-delayed contacts: Stop Category 1 Safety Category 3 Cross-fault monitoring Monitored or automatic start Suitable for use with light curtains Rated voltage: 230 / 115 / 42 VAC; 24 VAC/DC Plug-in terminal blocks |
F142 Multi-function Safety Monitor 7 N/O 4 N/C ContactsStop Category 0 Safety Category 4 7 N/O safety contacts 4 N/C signaling contacts 2 solid-state aux. outputs 6 diagnostic LEDs Cross-fault monitoring Monitored or automatic reset Suitable for light curtain and safety mat applications Removable terminal blocks |
F144 Safety Control ModuleStop Category 0 Safety Category 4 Can interface with F200 Series Output Modul 2 N/O safety contacts 2 N/C signaling contacts 2 solid-state switch outputs 6 diagnostic LEDs Cross-fault monitoring Monitored or automatic reset Also suitable for safety mats and light curtains Removable terminal blocks |
F200 Expandable Safety Relay SystemStop category 0 Safety category 4 Redundant microprocessor technology acc. EN 954-1 Up to 22 input circuits Monitored output modules Multiple combinations of modules available Activation and data transfer via com ports on front of modules Reduced space requirement Easy extendable Reduced wiring and assembly time Applicable for E-Stop, Safety gate, Safety mat and Light curtain activation in every combination |
M170 Measuring RelayVoltage monitoring for 3-phase networks Two setting ranges for response and release value Adjustable relay delay from 0-10s For networks with or without neutral conductor With optional phase sequence monitoring and signalling |
M220 Frequency and Stand Still MonitorFunction and parameter preselection Speed detection either via frequency input or evaluation of feedback voltage Measuring circuit monitoring Addittional programmable delay up to 24.9 seconds Easy-to-read LCD display Programming access through password |
M420 Motor Standstill MonitorStandstill detection through motor voltage feedback: rotation sensor not required Voltage feedback input safe up to 700VAC High accuracy through innova- tive microprocessor technology Adjustable relay delay up to 24.9 seconds per limit point Easy to read LCD display Password protected programming access |
M470 Measuring RelayOver- and under-voltage and phase imbalance limit points digitally programmable, independently of one another Phase sequence fault detection High repeatability through innovative microprocessor technology Voltage monitoring based on RMS measurement Adjustable relay delay up to 24.9 seconds per limit point Easy to read LCD display Password protected programming access |
Multi-range Timer With Circular Scale LCD Display 72x72Easy to read circular scale LCD display Convenient single-knob set-up of timing range and pre-set delay Six selectable timing ranges from 6 seconds to 60 hours Time Delay and Instantaneous Relays, each with N / O + N / C contacts Protected against accidental set- up changes Version V133T protected against power supply interruption |
E-Stop Relay and Safety Gate Monitor2 Safety contacts N/O Single- / dual - channel operation Crossfault monitoring Safety gate application Rated voltage: 230/115 / 42 VAC; 24 VAC/DC |